    平成29年4月10日作成
    

    医療機器回収(改修)の概要

    (クラスII)

  1. 一般名及び販売名

  2. 一般的名称: ビデオ硬性腹腔鏡
    販売名  : ENDOEYE硬性ビデオスコープ
    
    
  3. 対象ロット、数量及び出荷時期

  4. 製品名称:WA50040A
    製造番号:
    613116,613118,613120,614739,614750,614751,614783,614786,614812,614824,
    614825,614834,614835,615282,615367,615449,615450,615772,615774,616014,
    616016,616017,616038,616039,616040,616041,616332,616407,616895,616954,
    616958,616979,616983,616994,616995,616997,617059,617063,617089,617095,
    617098,617116,617117,617139,617141,617717,617732,617743,617772,617799,
    617803,617805,617837,617840,617852,617879,617882,617955,618930,618931,
    618949,618995,619016,619053,619056,619857,619858,619889,619985,619988,
    619994,619996,620002,620004,620005,620006,620580,620581,620615,620618,
    620619,620655,620656,620657,620658,620659,620665,620666,620865,620867,
    620992,621877,621923,622430,622432,622479,622528,622665,622668,624111,
    624159,624718,624728,624877,624906,625232,625233,625235,625277,625306,
    625307,625309,625310,625311,625312,625313,625349
    数  量:117台
    出荷時期:平成24年4月20日〜平成28年12月16日
    
    製品名称:WA50042A
    製造番号:
    613107,613111,613123,613124,613125,613126,613129,614662,614663,614664,
    614666,614672,614673,614675,614683,614684,614790,614798,614800,614801,
    614819,614838,614839,614840,614841,614842,615292,615305,615313,615315,
    615318,615332,615342,615346,615347,615348,615702,615705,615706,615712,
    615717,615718,615721,615727,615729,615733,615750,615752,615756,615760,
    615767,615769,615802,615811,615836,615839,615841,615842,615844,615845,
    615846,615853,615855,615856,615857,615858,615860,615861,615863,615865,
    615866,616367,616368,616370,616371,616374,616375,616383,616385,616391,
    616422,616423,616425,616426,616438,616440,616476,616478,616903,616911,
    616917,616918,616924,616926,616927,616966,616971,617016,617021,617022,
    617023,617030,617031,617045,617046,617055,617064,617076,617079,617083,
    617084,617085,617086,617088,617107,617108,617119,617123,617125,617127,
    617132,617133,617137,617169,617170,617171,617186,617694,617703,617707,
    617722,617723,617724,617725,617754,617767,617774,617778,617781,617785,
    617786,617787,617789,617790,617791,617820,617821,617822,617823,617824,
    617825,617827,617829,617893,617926,617936,617938,617939,617940,617966,
    618895,618897,618902,618957,618982,618986,619031,619047,619048,619050,
    619062,619072,619073,619076,619080,619081,619096,619097,619098,619099,
    619105,619116,619117,619120,619123,619124,619126,619127,619128,619129,
    619130,619136,619138,619139,619142,619146,619148,619149,619150,619151,
    619154,619155,619156,619157,619159,619730,619743,619744,619751,619754,
    619771,619773,619774,619965,620533,620567,620569,620612,620613,620632,
    620634,620636,620641,620642,620643,620644,620648,620651,620653,620696,
    620706,620708,620715,620716,620717,620718,620719,620725,620726,620727,
    620728,620729,620730,620731,620733,620734,620735,620800,620802,620803,
    620805,620806,620807,620808,620901,620902,620903,620966,621074,621075,
    621099,621831,621832,621862,621864,621939,621941,621942,621943,621961,
    621963,621965,621966,621968,622390,622391,622392,622399,622401,622403,
    622411,622423,622460,622492,622535,622536,622537,622538,622760,622761,
    622793,622796,623623,623640,623660,623744,623745,623746,623754,624032,
    624051,624052,624072,624092,624133,624135,624136,624137,624138,624139,
    624140,624141,624142,624153,624185,624191,624626,624671,624673,624688,
    624769,624774,624827,624828,624921,625225,625241,625242,625243,625244,
    625245,625246,625247,625248,625249,625250,625253,625254,625261,625265,
    625287,625296,625297,625316,625317,625318,625319,625326,625336,625338,
    625351,625353,625354,625355,625391,625393,625395,625937,625939,625940,
    625983,625985,625986,625987,626031
    数  量:365台
    出荷時期:平成24年3月22日〜平成29年1月7日
    
    
  5. 製造販売業者等名称

  6. 製造販売業者の名称 : オリンパスメディカルシステムズ株式会社 八王子事業所
    製造販売業者の所在地: 東京都八王子市石川町2951
    許可の種類     : 第一種医療機器製造販売業
    許可番号      : 13B1X00277
    
    
  7. 回収(改修)理由

  8. 本製品の挿入部先端には、使用中に対物レンズが曇ることを防止するため、ヒーターと温度センサが内蔵
    されています。
    製造業者(OLYMPUS Winter&Ibe社)から、温度センサが部分的に破損した場合、対象製品はヒーターによる
    加熱を制御できなくなり、挿入部が過度に加熱される可能性がある、との連絡を受けました。そのため、本
    製品の自主回収(改修)を実施することとしました。
    
    
  9. 危惧される具体的な健康被害

  10. ヒーターによる加熱を制御できなくなった場合、通常よりも挿入部先端の表面温度が過度に上昇し意図しない
    熱傷につながる可能性があります。
    しかしながら、添付文書にも記載されている通り、通常でも本製品の先端が熱くなるということは、使用者に
    認識されております。また、本製品は患者様の体腔内に挿入するものですが、直接患者様の組織に接触する
    ような使い方はしないため、通常、重篤な健康被害につながる可能性はないと考えております。
    更に本現象は社内での性能試験において限定的に発生しており、発生の可能性は低いと考えております。
    現在、本事象による健康被害は発生しておりません。
    
    
  11. 回収(改修)開始年月日

  12. 平成29年4月6日
    
    
    
  13. 効能・効果又は用途等

  14. 本品は、腹腔、後腹膜腔、胸腔等の体腔に挿入し、観察、診断、撮影、治療に用いることを目的とする。
    
    
  15. その他

  16. 本製品の納入施設は全て特定できておりますので、当社担当者が回収(改修)告知文を納入施設へ配布し、
    対象品を回収(改修)いたします。
    
    
  17. 担当者及び連絡先

  18. 担当者 : 医療国内安全管理部 鈴木 利雄
    連絡先 : オリンパスメディカルシステムズ株式会社
    
    電話番号: 03-6901-4014(直通)
    FAX番号 : 03-6901-3955