平成19年12月21日作成

医療機器 回収の概要

(クラスI)



  1. 一般名及び販売名

     一般的名称   :中心循環系人工血管
     販売名     :トリプレックス
     製造販売承認番号:21900BZY00013000
    
    
  2. 対象ロット、数量及び出荷時期

     製品コード :(1)TV-B402210 (2)TV-B402410 (3)TV-B402610 (4)TV-B402810
     シリアル番号:(1)TV-B402210 (46本)
             000875990,000875991,000875992,000875996,000875997,000875998
             000875999,000876000,000876001,000876002,000876003,000876004
             000876016,000876018,000876019,000876020,000876739,000876740
             000878278,000878302,000878304,000878626,000881199,000886377
             000886378,000887153,000887154,000887797,000887801,000887802
             000888035,000888056,000888057,000888058,000890093,000890094
             000890355,000890357,000890661,000890662,000890857,000890858
             000890859,000890860,000892478,000892479
            (2)TV-B402410(60本)
             000865435,000865438,000865440,000865794,000872277,000872278
             000872280,000872281,000872307,000876006,000876007,000876008
             000876009,000876022,000876023,000876044,000876045,000876728
             000876729,000876742,000876753,000876754,000876755,000878273
             000878274,000878296,000878297,000878298,000886373,000886374
             000886375,000886376,000886379,000886380,000886381,000886572
             000886574,000886575,000887155,000887163,000887164,000887169
             000887177,000887178,000887794,000887795,000887798,000890354
             000892476,000892477,000892484,000892489,000892490,000892491
             000892492,000892498,000892499,000892500,000892501,000894874
            (3)TV-B402610(63本)
             000875993,000875994,000875995,000876010,000876012,000876025
             000876026,000876027,000876030,000876031,000876033,000876034
             000876037,000876040,000876041,000876042,000876043,000876735
             000876736,000876747,000876748,000876749,000878250,000878257
             000878259,000878261,000878262,000878266,000878269,000878270
             000878275,000878277,000878287,000878288,000878290,000878291
             000878292,000878294,000878308,000878309,000878310,000878312
             000878313,000878314,000878316,000878317,000878318,000879298
             000881202,000887157,000887158,000887160,000887161,000887162
             000887165,000887166,000887468,000887793,000887804,000888037
             000892475,000894876,000894877
            (4)TV-B402810 (65本)
             000865443,000865444,000865446,000865452,000865457,000865747
             000865755,000865784,000865785,000865786,000865789,000865790
             000865791,000865792,000872271,000872287,000872288,000872289
             000875988,000876013,000876014,000876038,000876039,000876731
             000876732,000876733,000876745,000876746,000878247,000878271
             000878272,000878299,000886312,000886313,000886315,000886316
             000887168,000887171,000887172,000887173,000887174,000887175
             000887176,000887466,000887786,000887787,000887788,000888028
             000888029,000888038,000888039,000888040,000888042,000888043
             000888593,000888594,000888595,000888596,000888597,000888602
             000888603,000888604,000888605,000890358,000890361
     出荷数量  :234本
     出荷時期  :平成19年10月30日 〜 平成19年12月14日
    
    
  3. 製造販売業者等名称

     製造販売業者 :テルモ株式会社
     所在地    :東京都渋谷区幡ヶ谷2−44−1
     許可の種類  :第1種医療機器製造販売業
     許可番号   :13B1X00101
     輸入先製造業者:バスクテック社(英国)
    
    
  4. 回収理由

     国内の医療機関において当該製品の植込み手術中に発生した血液漏出事例を受け、輸入
    製造元において調査を行った結果、分枝管の縫合作業工程において、縫合品と未縫合品が
    混入し、また、その後の分枝管の縫合の確認工程において、未縫合品が見逃され出荷され
    たことが判明したため、自主回収を開始することと致しました。
    
    
  5. 危惧される具体的な健康被害

     本不具合が発現した場合、製品の分枝管の接合部に亀裂が生じ、血液が漏出し、重篤な
    健康被害が発現する恐れがあります。ただし、平成19年12月20日現在において、健康被害
    の発生報告は受けておりません。
     これまでに確認された臨床現場において発生した当該事象は1件のみであり、健康被害
    は発生しておりません。
    
    
  6. 回収開始年月日

      平成19年12月15日(情報提供の開始)
    
    
  7. 効能・効果又は用途等

     本品は、動脈瘤又は閉塞性疾患の動脈の置換又は、修復を目的に、永久的に留置して使
    用する合成繊維製人工血管である。
    
    
  8. その他

     回収対象製品を採用している医療施設は全て特定していますので、弊社担当者が直接対
    象施設を訪問することにより情報提供を行うと同時に製品を回収いたします。また、既に
    使用された製品につきましては、担当医師を通じ、速やかに患者様のモニタリング(経過
    観察)を実施いたします。
    
    